Circuit Diagram
Notes
Notes
- Power the circuit from a 3V battery.
- Two metal wires 10 cm long and 5cm apart driven into the soil will do the job for probes.
- The probes are to be connected at the terminals A and B shown in circuit.
- Capacitors C1 and C2 must be polyester type.
- The IC U1 is a quad two input Schmitt NAND IC 4093.
- The sensitivity can be adjusted by varying the preset R2.
- Mount the IC on a holder.